Comparison of Non-mydriatic Fundus Photography and Optical Coherence Tomography with Dilated Fundus Examination for Detecting Diabetic Retinopathy Including Diabetic Macular Edema
Fundus Photography versus OCT in DR
Vol. 17 No. 1 : 2022 (88-104)
Abstract
Given increasing diabetes rates worldwide, better screening tools for diabetic retinopathy (DR) and macular edema (DME) are needed. The study aim was to compare reliability and predictive values between non-mydriatic fundus photography (NMFP) and spectral-domain optical coherence tomography (OCT) for detection of DR and DME with dilated fundus examination (DFE). This was a non-interventional, comparative study. Diabetics underwent both NMFP and macula OCT, followed by DFE. Images were interpreted by two masked ophthalmologists. The DFE result was considered gold standard. One hundred and fifty-four eyes of 83 patients were recruited. Sensitivity of NMFP for DR was 77.3% and 80.3% for OCT. Specificity for NMFP was 81.8% and 55.7% for OCT. Area under Receiver Operating Characteristics Curve (AROC) for DR was 0.80 for NMFP and 0.68 for OCT. The sensitivity of NMFP for DME was 63.2% and 82.5% for OCT. Specificity for DME was 90.1% by NMFP and 61.5% for OCT. Positive predictive value (PPV) of NMFP and OCT for DR was 76.1% (95% CI: 63.9-85.3%) and 57.6% (46.8-67.7%), respectively. Negative predictive value (NPV) of NMFP and OCT was 82.7% (95% CI: 72.8-89.7%) and 79.0% (66.4-87.9%) respectively. Positive predictive value of NMFP and OCT for DME was 80.0% (95% CI: 67.6-88.5%) and 57.3% (45.9-68.0%), respectively. Negative predictive value of NMFP and OCT was 79.6% (95% CI:70.3 - 86.7%) and 84.8% (95% CI:73.4 - 92.1%), respectively. Eyes with normal OCT miss 21% of DR. In conclusion, NMFP is better than OCT for DR screening, while OCT is better than NMFP and DFE for detection of DME. Both modalities should be for better DR screening.
Keywords :
diabetic macular edema,
diabetic maculopathy,
diabetic retinopathy,
fundus photography,
optical coherence tomography,
Correspondance Address
Prof. Dr. Mae-Lynn Catherine Bastion. Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia. Tel: +6019-3200763; +603-9145 5981 Email: maelynnb2003@yahoo.com
References
Abougalambou, S.S., Abougalambou, A.S. 2015. Risk factors associated with diabetic retinopathy among type 2 diabetes patients at teaching hospital in Malaysia. Diabetes Metab Syndr 9(2): 98-103.
Ahmed, J., Ward, T.P., Bursell, S.E., Aiello, L.M., Cavallerano, J.D., Vigersky, R.A. 2006. The sensitivity and specificity of nonmydriatic digital stereoscopic retinal imaging in detecting diabetic retinopathy. Diabetes Care 29(10): 2205-9.
American Academy of Ophthalmology. 2019. American Academy of Ophthalmology Retina and Vitreous Panel. Preferred Practice Pattern® guidelines. Diabetic retinopathy. San Francisco, CA: American Academy of Ophthalmology.
Aptel, F., Denis, P., Rouberol, F., Thivolet, C. 2008. Screening of diabetic retinopathy: Effect of field number and mydriasis on sensitivity and specificity of digital fundus photography. Diabetes Metab 34(3): 290-3.
Azrak, C., Baeza-Díaz, M.V., Palazón-BruA, Hernández-Martínez, C., Navarro-Navarro, A., Martínez-Toldos, J.J., Gil-Guillén, V.F. 2015. Validity of Optical Coherence Tomography as a Diagnostic Method for Diabetic Retinopathy and Diabetic Macular Edema. Medicine (Baltimore) 94(38): e1579.
Bawankar, P., Shanbhag, N., K, S.S., Dhawan, B., Palsule, A., Kumar, D., Chandel, S., Sood, S. 2017. Sensitivity and specificity of automated analysis of single-field non-mydriatic fundus photographs by Bosch DR Algorithm-Comparison with mydriatic fundus photography (ETDRS) for screening in undiagnosed diabetic retinopathy. PLoS One 12(12): e0189854.
D’Aloisio, R., Giglio, R., Di Nicola, M., De Giacinto, C., Pastore, M.R., Tognetto, D., Peto, T. 2019. Diagnostic Accuracy of Digital Retinal Fundus Image Analysis in Detecting Diabetic Maculopathy in Type 2 Diabetes Mellitus. Ophthalmic Res 61(2): 100-6.
Goh, J.K., Cheung, C.Y., Sim, S.S., Tan, P.C., Tan, G.S, Wong, T.Y. 2016. Retinal Imaging Techniques for Diabetic Retinopathy Screening. J Diabetes Sci Technol 10(2): 282–94.
Guidelines Development Group. 2011. Clinical Practice Guidelines: Screening for Diabetic Retinopathy. Ministry of Health Malaysia. http://www.moh.gov.my [November 2011]
Gupta, V., Bansal, R., Gupta, A., Bhansali, A. 2014. Sensitivity and specificity of nonmydriatic digital imaging in screening diabetic retinopathy in Indian eyes. Indian J Ophthalmol 62(8): 851-6.
Hussein, Z., Taher S.W., Gilcharan Singh, H.K., Chee Siew Swee W. 2016. Diabetes Care in Malaysia: Problems, New Models, and Solutions. Ann Glob Health 81(6): 851-62.
Keenan, T.D., Johnston, R.L., Donachie, P.H., Sparrow, J.M., Stratton, I.M., Scanlon, P. 2013. United Kingdom National Ophthalmology Database Study: Diabetic Retinopathy; Report 1: prevalence of center-involving diabetic macular edema and other grades of maculopathy and retinopathy in hospital eye services. Eye (Lond) 27(12): 1397-404.
Lang, G.E. 2007. Optical Coherence Tomography Findings in Diabetic Retinopathy: Developments in Ophthalmology 39: 31-47.
Gella, L., Raman, R., Rani, P.K., Sharma, T. 2014. Spectral domain optical coherence tomography characteristics in diabetic retinopathy. Oman J Ophthalmol 7(3): 126-9.
Lin, D.Y., Blumenkranz, M.S., Brothers, R.J., Grosvenor, D.M. 2002. The Digital Diabetic Screening Group. The sensitivity and specificity of single-field nonmydriatic monochromatic digital fundus photography with remote image interpretation for diabetic retinopathy screening: a comparison with ophthalmoscopy and standardized mydriatic color photography. Am J Ophthalmol 134(2): 204-13.
Lopez-Bastida, J., Cabrera-Lopez, F., Serrano-Aguilar, P. 2007. Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy. Diabet Med 24(4): 403-7.
Mizrachi, Y., Knyazer, B., Guigui, S., Rosen, S., Lifshitz, T., Belfair, N., Klemperer, I., Schneck, M., Levy, J. 2014. Evaluation of diabetic retinopathy screening using a non-mydriatic retinal digital camera in primary care settings in South Israel. Int Ophthalmol 34(4): 831-7.
Neubauer, A.S., Kernt, M., Haritoglou, C., Priglinger, S., Kampik, A., Ulbig, M.W. 2008. Nonmydriatic screening for diabetic retinopathy by ultra-widefield scanning laser ophthalmoscopy (Optomap). Graefes Arch Clin Exp Ophthalmol 246(2): 229-35.
Piyasena, M.M.P.N., Yip, J.L.Y., MacLeod, D., Kim, M., Gudlavalleti, V.S.M. 2019. Diagnostic test accuracy of diabetic retinopathy screening by physician graders using a hand-held non-mydriatic retinal camera at a tertiary level medical clinic. BMC Ophthalmol 19(1): 89.
Rani, P.K., Bhattarai, Y., Sheeladevi, S., ShivaVaishnavi, K., Ali, M.H., Babu, J.G. 2018. Analysis of yield of retinal imaging in a rural diabetes eye care model. Indian J Ophthalmol 66(2): 233-7.
Roser, P., Kalscheuer, H., Groener, J.B., Lehnhoff, D., Klein, R., Auffarth, G.U., Nawroth, P.P., Schuett, F., Rudofsky, G. 2016. diabetic retinopathy screening ratio is improved when using a digital, nonmydriatic fundus camera onsite in a diabetes outpatient clinic. J Diabetes Res 2016: 4101890.
Stewart, M.W. 2016. Treatment of diabetic retinopathy: Recent advances and unresolved challenges. World J Diabetes. 7(16): 333-41.
Virgili, G., Menchini, F., Casazza, G., Hogg, R., Das, R.R., Wang, X., Michelessi, M. 2015. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy. Cochrane Database Syst Rev 1: CD008081
Wan Nazaimoon, W.M., Md Isa, S.H., Wan Mohamad, W.B., Khir, A.S., Kamaruddin, N.A., Kamarul, M., Mustafa, N., Ismail, I.S., Ali, O., Khalid, B.A. 2013. Prevalence of diabetes in Malaysia and usefulness of HbA1C as a diagnostic criterion. Diabet Med 30(7): 825-8.
Wilkinson, C.P., Ferris, F.L., Klein, R.E., Lee, P.P., Agardh, C.D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., Verdaguer, J.T.; Global Diabetic Retinopathy Project Group. 2003. Proposed International Clinical Diabetic Retinopathy and Diabetic Macular Edema Disease Severity Scales. Ophthalmology 110(9): 1677-82
Wu, L., Fernandez-Loaiza, P., Sauma, J., Hernandez-Bogantes, E., Masis, M. 2013 Classification of diabetic retinopathy and diabetic macular edema. World J Diabetes 4(6): 290-4.