The Estimation of Fetomaternal Haemorrhage by Flowcytometry
The Estimation of Fetomaternal Haemorrhage by Flowcytometry
Vol. 10 No. 2 : 2015 (112-122)
Abstract
Fetomaternal haemorrhage (FMH) may occur following a sensitizing event, during pregnancy or at delivery. In cases of rhesus (Rh) incompatibility between mother and the fetus, it can thus subject to the haemolytic disease of the newborn. The Kleihauer test for quantification of FMH lacks standardization and results are less accurate. Furthermore, it cannot differentiate the fetal cell from the adult HbF. Flowcytometry analysis using monoclonal antibodies, is a new technique for the quantification of FMH and it allows larger number of cells to be analysed. It is also able to differentiate the fetal cell from maternal HbF, and thus is more sensitive and accurate. The objective of our study was to determine the FMH using the flowcytometric analysis of anti-HbF antibody and to correlate the FMH using flow cytometry and the standard Kleihauer test. Ninety eight peripheral blood samples from pregnant women at more than 20 weeks of pregnancy and post delivery were analyzed by both methods. The percentage of the fetal cells were recorded and the FMH were calculated. We found a fair correlation between the two methods with the correlation coefficient r = 0.633 (p<0.05). The concordance rate was 66.3%. Flow cytometric method, however, gave higher values in 70.4% of cases as compared to the Kleihauer test. These could be due to the autofluoresce of contaminated white blood cell or using anti HbF which is less specific than anti-D. Other possible factors could be due to the fluorochrome used. Therefore, in order to increase the accuracy, we recommend the use of dual labeling of red cells with glycophorin A which is a marker for red cells and compare the use of monoclonal anti HbF and anti-D for analysis.
Keywords :
anti HbF,
fetomaternal haemorrhage,
flowcytometry,
Kleihauer test,
Correspondance Address
Dr. Nurasyikin Yusof, Department of Pathology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia. Tel: +603-91455373 Fax: +603-91459483 Email: syikinby@gmail.com
References
Augustson, B.M., Fong, E.A., Grey, D.E., Davies, J.I., Erber, W.N. 2006. Postpartum anti-D: can we safely reduce the dose?. Med J Aust 184(12): 611-3.
Bayliss, K.M., Kueck, B.D., Johnson, S.T., Fueger, J.T., McFadden, P.W., Mikulski, D., Gottschall, J.L. 1991. Detecting fetomaternal haemorrhage: a comparison of five methods. Transfusion 31(4): 303-7.
BCSH Blood Transfusion and General Haematology Task Force. 2011. Guidelines for the Estimation of Fetomaternal Haemorrhage. www.bcshguidelines.com. [Access date]
Bromilow, I.M., Duguid, J.K. 1997. Measurement of feto-maternal haemorrhage: a comparative study of three Kleihauer techniques and two flow cytometric methods. Clin Lab Haematol 19(2): 137-142.
Brown, M., Wittwer, C. 2000. Flow cytometry: principles and clinical applications in haematology. Clin Chem 46(8 Pt 2): 1221-9.
Corsetti, J.P., Cox, C., Leary, J.F., Cox, M.T., Blumberg, N., Doherty, R.A. 1987. Comparison of quantitative acid-elution technique and flow cytometry for detecting fetomaternal haemorrhage. Ann Clin Lab Sci 17(3):197-206.
Davis, B.H., Olsen, S., Bigelow, N.C., Chen, J.C. 1998. Detection of fetal red cells in fetomaternal haemorrhage using a fetal haemoglobin monoclonal antibody by flow cytometry. Transfusion 38(8): 749-56.
Duckett, J.R., Constantine, G. 1997. The Kleihauer technique: an accurate method of quantifying fetomaternal haemorrhage? Br J Obstet Gynaecol 104(7): 845-6.
Duguid, J.K., Bromilow, I.M. 1999. Laboratory measurement of fetomaternal haemorrhage and its clinical relevance. Transfus Med Rev 13(1): 43-8.
Janssen, W.C., Hoffmann, J.J. 2002. Evaluation of flow cytometric enumeration of foetal erythrocytes in maternal blood. Clin Lab Haematol 24(2): 89-92.
Johnson, P.R., Hudson, C., Lee, D. 1993. The quantification of feto-maternal haemorrhage using flow cytometry. British Journal of Haematology 84(1): 48.
Johnson, P.R., Tait, R.C., Austin, E.B., Shwe, K.H., Lee, D. 1995. Flow cytometry in diagnosis and management of large fetomaternal haemorrhage. J Clin Pathol 48(11): 1005-8.
Kennedy, G.A., Shaw, R., Just, S., Bryson, G., Battistutta, F., Rowell, J., Williams, B. 2003. Quantification of feto-maternal haemorrhage (FMH) by flow cytometry: anti-fetal haemoglobin labeling potential underestimates massive FMH in comparison to labeling with anti-D. Transfus Med 13(1): 25-33.
Kleihauer, E., Braun, H., Betke, K. 1957. Demonstration of fetal haemoglobin in erythrocytes by elution. Klin Wochenschr 35(12): 637-8.
Lloyd-Evans, P., Guest, A.R., Austin, E.B., Scott, M.L. 1999. Use of a phycoerythrin-conjugated anti-glycophorin A monoclonal antibody as a double label to improve the accuracy of FMH quantification by flow cytometry. Transfus Med 9(2): 155-160.
Mollison, P.L. 1972. Quantitation of transplacental haemorrhage. Br Med J 3(5818): 115.
Nance, S.J., Nelson, J.M., Arndt, P.A., Lam, H.C., Garratty, G.1989. Quantitation of fetal-maternal haemorrhage by flow-cytometry. Am J Clin Pathol 91(3): 288-92.
National Blood Transfusion Service Immunoglobulin Working Party. Recommendations for the use of anti-D immunoglobulin. Prescribers’ Journal 1991;31:137-45
